EPDM Rubber Roof Repair November 2015

November 2015

Preparation:

Carefully chase out abutment walls. Supply and fit new code 4 lead flashing as required.

Carefully remove coping stones.

Remove all loose chippings, bag up and remove from roof area ready for disposal. Prepare roof ready to receive new polyurethane insulated recovery boards.

Roofdeck Insulation Specification

Supply and lay 50mm high performance insulated recovery boards over existing felt. The felt will be utilised as the vapour barrier.

Thermal Roof Premium Reinforced Rubber System Fully Adhered

Supply and lay premium reinforced EPDM rubber membrane over whole roof area, fully adhered to the prepared surface.

 

 

 

Flat Roof Repairs Weston super Mare EPDM Rubber Roof Garage Repairs Somerset 1Flashing to Walls

At abutment walls, dress membrane up and under lead flashings. The rubber is to be adhered using special contact adhesive.

Dress membrane up over wall, and finish using black metal profile trim.

 

Standard Drip Profile Black

Dress membrane to external roof water outlets.

 

Removal of debris from site

We will arrange for the removal of all debris from site.

 

View the gallery of the EPDM flat roof project below

Flat Roof Guarantees

All Thermal flat roof installations are covered by our Company 25 year guarantee.

Health and Safety

Thermal Roof will ensure compliance of safe working practice in accordance with the health and safety at work act 1974, and the guidance of the Health and Safety Executive.

 

Thermal Roof YouTube Channel